Hi Slartibartfast and All,Thanks for helping me out.This is the below scheme which I am thinking will just do the picking of samples. I am just worried about the...
Hi All,To clarify the specific question about the input and outputs. The input sampling rate is ~10 kHz, and the input content is within ~10 Hz. The data needs to...
Hi All,The general method used for fractional rate conversion is to use a polynomial based filtering of the input data like a Farrow structure. This structures are...
You need to look at integrated noise after the filter which is given by (m0)*(equivalent noise bandwidth of filter). For example: if you use a first order filter,...
Hi ShahramThe Digital DSM is part of a two point injection modulator. The topology of the DSM was finalized from system level simulations in Matlab. But it is an...
Hi,In the attached DSM MOD-2_DSM, how does one determine the bit-widths? Is there analytical relation of bitwidth in relation to the input bitwidth? How does one...
Hi Tim,Thanks for your reply. So if all loops are stable then the complete closed loop is stable. I am also of the same opinion. But I think this is a sufficient...
Hi JOS,Thanks for your reply. Is there a criteria how large the eigenvalues can be for a particular performance? What I mean is, for continuous time single loop...