DSPRelated.com
Forums

Help me in designing XBUS of 6204

Started by Ramanan August 23, 2002
Hi DSPers,
I am using TMS320C6204 DSP to process data read from a FIFO. The FIFO is
to be connected as glue less interface through the Expansion bus of the
DSP (in XCE3 space). The FIFO we are going to use is from IDT. Is the
6204 DSP compatible with the IDT FIFO? Also I have planned to operate
the XBUS with the internal arbiter enabled. In this mode, what should be
done to the signals XHOLD and XHOLDA? Should I pull it down? I am not
using the Host port interface of the XBUS. I think the XHOLD and XHOLDA
signals are meant for HPI. Please any body who knows help me.
Also I have designed my own board. I need some help for designing the
power capacitors.
S.K.Ramanan,

Project Engineer,

Soliton Automation Pvt Ltd.,

Coimbatore.

India.



Ramanan-

> I am using TMS320C6204 DSP to process data read from a FIFO. The FIFO is
> to be connected as glue less interface through the Expansion bus of the
> DSP (in XCE3 space). The FIFO we are going to use is from IDT. Is the
> 6204 DSP compatible with the IDT FIFO? Also I have planned to operate
> the XBUS with the internal arbiter enabled. In this mode, what should be
> done to the signals XHOLD and XHOLDA? Should I pull it down? I am not
> using the Host port interface of the XBUS. I think the XHOLD and XHOLDA
> signals are meant for HPI. Please any body who knows help me.

Suggest that you use a sufficient size logic device, and put the FIFO(s) in the
logic. YOu will need a number of control signals, state-machines, etc. to
handle
synchronous X-Bus transfers, so you got to have the logic anyway. Why use a
separate
FIFO IC? Keep the design simple and flexible.

Jeff Brower
DSP sw/hw engineer
Signalogic